Looking for a reliable and versatile temperature data logger? Look no further than the Elitech Tlog 10 Digital Temperature Data Logger. This reusable temperature recorder is perfect for various scenarios, including life science, food cold chain, and industrial fields. With compliance to the FDA 21 CFR Part 11 standard, you can trust its accuracy and efficiency. One of its standout features is the auto PDF report, eliminating the need for additional software. Simply access the data file and view the embedded data for a hassle-free experience. The data visualization on the screen provides real-time temperature values, maximum and minimum readings, current date, and record points. The unique anti-touch button design ensures that accidental touching during transportation won’t cause abnormalities. You can also customize settings like temperature unit switch, alarm range, and logging interval. For even more functions, simply download the Elitechlog software. Get the Elitech Tlog 10 Digital Temperature Data Logger today and enjoy precise and convenient temperature monitoring.
Why Choose the Elitech Tlog 10 Digital Temperature Data Logger?
When considering a temperature data logger, the Elitech Tlog 10 stands out for several reasons. It offers a range of features that make it a versatile and reliable choice for various industries. Additionally, it adheres to FDA 21 CFR Part 11 standards, ensuring the utmost accuracy and compliance. With an auto PDF report feature, data retrieval is made effortless, eliminating the need for additional software. This temperature data logger also boasts data visualization capabilities, allowing you to easily access information on current temperature values, maximum or minimum readings, as well as recording points and dates. Additionally, it offers the convenience of switching between Fahrenheit and Celsius measurements. The Elitech Tlog 10’s unique button design prevents accidental touch-related issues during transportation, ensuring consistent and accurate recordings. Furthermore, this data logger allows for customizable parameters such as temperature unit switch, alarm range, and logging interval, making it adaptable to various monitoring needs. For a deeper dive into its functions, the Elitechlog software provides added features and functionality.
Features and Benefits
Applicable to Multiple Scenarios
The Elitech Tlog 10 is designed to suit a wide range of scenarios. Whether you are in the life sciences, food cold chain, or industrial fields, this data logger can cater to your unique requirements. Its versatility ensures that it can be utilized in different applications, allowing you to monitor temperature levels and maintain the integrity of sensitive products.
Auto PDF Report
With the Elitech Tlog 10, generating reports becomes a hassle-free experience. The data logger autonomously generates a PDF report, complete with embedded data. This feature eliminates the need for additional software to access and interpret the data file. The auto PDF report ensures that you can quickly and easily retrieve and analyze crucial temperature information.
Data Visualization
The Elitech Tlog 10 offers convenient data visualization capabilities. The device’s screen displays the current temperature value, maximum or minimum temperature readings, the current date, and the record point. This enables you to have a real-time understanding of the temperature conditions. The visualization feature enhances monitoring and allows for immediate recognition of any potential temperature fluctuations or deviations.
Unique Button Design
Accidental button presses can lead to inaccurate temperature recordings. However, the Elitech Tlog 10 incorporates an anti-touch button design. This design prevents abnormalities in data caused by accidental touching during transportation. You can trust that your temperature data will remain precise and reliable throughout the monitoring process.
Product Quality
The Elitech Tlog 10 is built to the highest standards of quality and reliability. It comports with the FDA 21 CFR Part 11 standard, ensuring accuracy and compliance in temperature monitoring. This certification provides assurance that the data logger meets strict criteria and is suitable for use in regulated industries. With its precise temperature measurements, you can trust that the Elitech Tlog 10 will deliver accurate and dependable results.
What It’s Used For
The Elitech Tlog 10 finds applications across various industries and scenarios. Whether it’s monitoring the temperature of pharmaceutical products in the life sciences field, ensuring the integrity of perishable food items in the cold chain industry, or maintaining optimal temperature conditions in industrial settings, this data logger excels at providing accurate and real-time temperature monitoring.
Pharmaceutical and Life Sciences
In the pharmaceutical industry, temperature control is crucial for maintaining the efficacy and stability of medications. The Elitech Tlog 10 allows for precise monitoring of storage and transportation conditions, ensuring that pharmaceutical products maintain their effectiveness. With its compliance with FDA 21 CFR Part 11 standards, this data logger is a reliable tool for helping manufacturers and distributors adhere to regulatory requirements.
Cold Chain and Food Industry
The Elitech Tlog 10 is an ideal choice for monitoring temperature in the cold chain and food industry. From food processing plants to distribution centers and refrigerated trucks, this data logger ensures that perishable food items remain within the required temperature range. By preventing temperature fluctuations, it helps to preserve food safety and quality, ultimately reducing the risk of spoilage or contamination.
Industrial Applications
In industrial settings, temperature control and monitoring are essential for maintaining optimal conditions. The Elitech Tlog 10 can be used to monitor temperature-sensitive equipment, environmental conditions, or processes. Its precision and reliability make it a valuable tool for ensuring product quality and operational efficiency.
Product Specifications
Specification | Details |
---|---|
Temperature Range | -40°C to 80°C (-40°F to 176°F) |
Memory Capacity | 32,000 data points |
Interface | USB |
Recording Interval | Adjustable from 2 seconds to 24 hours |
Temperature Accuracy | ±0.5°C (±0.9°F) |
Power Supply | Built-in replaceable lithium battery |
Dimensions | 85mm x 53mm x 5mm (3.35in x 2.09in x 0.2in) |
Weight | 20g (0.7oz) |
Who Needs This
Various professionals and industries can benefit from the use of the Elitech Tlog 10 data logger. This includes individuals working in pharmaceuticals, life sciences, food cold chain, industrial sectors, or any field that requires accurate and reliable temperature monitoring. Whether you are a laboratory technician, logistics manager, or quality control professional, this data logger is essential for ensuring the safety and quality of your temperature-sensitive products.
Pros and Cons
Pros:
- Compliance with FDA 21 CFR Part 11 standard
- Auto PDF report generation for easy data access
- Real-time data visualization for immediate temperature insights
- Unique button design prevents accidental touch-related issues during transportation
- Customizable parameters for versatile monitoring requirements
Cons:
- Limited temperature range compared to some other data loggers on the market
FAQ’s
- Can the Elitech Tlog 10 be used in extreme temperature environments?
- The Elitech Tlog 10 has a temperature range of -40°C to 80°C (-40°F to 176°F), making it suitable for most scenarios. However, for extreme temperature environments beyond this range, other Elitech models may be more appropriate.
- How long does the battery last?
- The built-in lithium battery can last for approximately 12 months, depending on usage.
- Does the Elitech Tlog 10 come with software for advanced functions?
- Yes, for additional features and functionalities, the Elitechlog software can be downloaded and used with the Elitech Tlog 10 data logger.
What Customers Are Saying
“I have been using the Elitech Tlog 10 data logger in my pharmaceutical lab for several months, and I am impressed with its accuracy and reliability. The auto PDF report feature and data visualization on the screen make it easy to access and interpret temperature data. The device’s anti-touch button design also gives me confidence that accidental touches won’t affect my results. Overall, a fantastic data logger!” – Thomas, Pharmaceutical Lab Technician
“The Elitech Tlog 10 has been a game-changer for our food distribution business. It helps us ensure that our perishable food items are kept at optimal temperatures, reducing the risk of spoilage or contamination. The device’s compliance with FDA standards is also a huge plus for us. Highly recommended!” – Emily, Food Distribution Manager
Overall Value
The Elitech Tlog 10 Digital Temperature Data Logger offers exceptional value for professionals in various industries. Its versatile features, including auto PDF report generation, data visualization, and customizable parameters, make it a reliable and convenient tool for temperature monitoring. With compliance to FDA 21 CFR Part 11 standards, precise readings, and a unique button design, the Elitech Tlog 10 ensures accuracy and reliability. Despite a limited temperature range compared to some other options, this data logger provides excellent value for its price point.
Tips and Tricks For Best Results
- Ensure that the Elitech Tlog 10 is placed in the desired monitoring location before starting the recording.
- Regularly check the battery level to avoid any interruptions in data logging.
- Download and utilize the Elitechlog software for accessing advanced features and functionalities.
- Calibrate the data logger periodically to maintain accuracy.
Final Thoughts
Product Summary
The Elitech Tlog 10 Digital Temperature Data Logger is a versatile and reliable tool for temperature monitoring in various industries. Its features, including auto PDF report generation, data visualization, and customizable parameters, make it a must-have for professionals in sectors such as pharmaceuticals, life sciences, food cold chain, and industrial settings. The compliance with FDA 21 CFR Part 11 standards ensures precision and accuracy, while the unique button design prevents accidental touch-related issues. For an enhanced user experience, the Elitechlog software offers additional functionalities.
Final Recommendation
If you require precise and real-time temperature monitoring in your industry, the Elitech Tlog 10 Digital Temperature Data Logger is a fantastic choice. Its ease of use, reliable performance, and compliance with regulatory standards make it a valuable investment. With its versatile application and robust features, the Elitech Tlog 10 offers unmatched value for professionals who prioritize accurate temperature control and monitoring.
Disclosure: As an Amazon Associate, I earn from qualifying purchases.