If you’re in need of a reliable and user-friendly current data logger, look no further than the AEMC CL601 Simple Logger II Single-Channel Clamp-On Current Data Logger. With its self-contained design and no exposed connections, this logger offers easy-to-use operation at just the touch of a button. Equipped with TRMS measurements and overload indication, you can trust that your measurements will be accurate and secure. The optically isolated USB 2.0 connection ensures convenient data transfer, while the wide input range of 0 to 600A RMS makes this logger suitable for a variety of applications. With a maximum voltage rating of 300V Cat. IV and 600V Cat. III, you can have peace of mind knowing that this logger can handle even the toughest environments.
Why Consider This Product?
If you’re looking for a reliable and user-friendly clamp-on current data logger, the AEMC CL601 Simple Logger II is a top choice. This product offers multiple features and benefits that make it a valuable tool for various applications. Whether you’re an electrician, engineer, or simply someone who needs to measure and log current data, this product can meet your needs effectively.
The AEMC CL601 Simple Logger II has been proven to deliver accurate measurements with its true RMS measurement capability. It eliminates the need for exposed connections, ensuring safety during operation. With its easy one-button operation, you’ll find it incredibly convenient to use. In case of overload, the logger provides an indication and alarm function, alerting you to potential risks. Furthermore, the optically isolated USB 2.0 allows for seamless data transfer.
Features and Benefits
Reliable Measurements with True RMS
With true RMS measurements, the AEMC CL601 Simple Logger II ensures accurate readings under various conditions. This feature is essential for professionals who require precise data for analysis or troubleshooting purposes.
Easy-to-Use One Button Operation
The user-friendly design of this data logger simplifies its operation. The one-button control makes it incredibly easy to start and stop measurements, eliminating any confusion or complex procedures.
Safety First with Overload Indication and Alarm Function
The CL601 Simple Logger II comes equipped with an overload indication and alarm function. This ensures that you are always aware of potential risks or abnormal current levels, allowing you to take necessary precautions promptly.
Secure Data Transfer with Optically Isolated USB 2.0
Effortlessly transfer your data to a computer or other devices using the optically isolated USB 2.0 port. This feature ensures reliable and secure data transfer, protecting the integrity of your measurements.
Product Quality
The AEMC CL601 Simple Logger II is built with high-quality materials and has undergone rigorous testing to ensure its durability and reliability. It is designed to withstand demanding environments, making it suitable for both indoor and outdoor use. Backed by AEMC’s reputation for producing top-notch instruments, you can trust in the quality of this product.
What It’s Used For
Energy Auditing
Monitor and record current consumption in commercial or residential buildings for energy auditing purposes. The CL601 Simple Logger II allows you to track energy usage accurately, helping identify areas for energy-saving improvements.
Equipment Testing and Maintenance
Use this data logger for equipment testing and maintenance in industrial settings. Measure and log current data for motors, generators, transformers, and other machinery to ensure their optimal performance and detect any abnormalities.
Power Quality Analysis
The CL601 Simple Logger II provides valuable data for power quality analysis. Monitor current levels, detect voltage harmonics, and analyze power factor to identify and resolve any power quality issues that may affect equipment performance or cause electrical faults.
Electrical Troubleshooting
When troubleshooting electrical systems, it is essential to have accurate current measurements. This data logger allows you to capture current data effortlessly and analyze it for potential issues or imbalances, helping you solve electrical problems efficiently.
Product Specifications
Here is a table showcasing the technical specifications of the AEMC CL601 Simple Logger II:
Specifications | |
---|---|
RMS Input Range | 0 to 600A |
Maximum Voltage | 300V Cat. IV; 600V Cat. III |
USB Interface | Optically Isolated USB 2.0 |
Logger Type | Single Channel |
Certification | CE, UL |
Weight | Approximately 1.5 lbs |
Dimensions | 8.25″ x 4.25″ x 2.68″ |
Who Needs This?
The AEMC CL601 Simple Logger II is a versatile tool suitable for professionals in various fields. Electricians, engineers, maintenance technicians, energy auditors, and anyone involved in electrical systems will benefit from this data logger. Whether you need accurate current measurements for monitoring energy consumption or power quality analysis, this product is an ideal choice.
Pros and Cons
Pros:
- Accurate true RMS measurements
- Easy one-button operation
- Overload indication and alarm function for safety
- Secure data transfer with optically isolated USB
- Durable and reliable construction
Cons:
- Single-channel capability may limit simultaneous measurements for certain applications
- May require additional clamps or accessories for specific current ranges
FAQ’s
Q: Can I measure AC and DC currents with the AEMC CL601 Simple Logger II? A: No, this data logger is designed specifically for AC current measurements.
Q: What is the maximum current that this logger can measure? A: The CL601 Simple Logger II has a maximum RMS input range of 600A.
Q: Can I use this data logger for high-voltage applications? A: The logger is rated for maximum voltages of 300V Cat. IV and 600V Cat. III, making it suitable for a wide range of electrical applications.
What Customers Are Saying
Customer testimonials highlight the reliability and ease of use of the AEMC CL601 Simple Logger II. Many users appreciate its one-button operation and the accuracy of its measurements. Customers also praise the product’s durability and the convenience of the optically isolated USB for data transfer.
Overall Value
Considering the features, ease of use, and durability, the AEMC CL601 Simple Logger II offers excellent value for its price. It provides accurate measurements, ensures safety, and simplifies data analysis. Whether you’re a professional or a DIY enthusiast, this data logger is a valuable tool to have in your toolkit.
Tips and Tricks for Best Results
- Familiarize yourself with the user manual to fully understand the functionality and operation of the data logger.
- Ensure that the clamp is properly placed around the current-carrying conductor for accurate measurements.
- Regularly calibrate the data logger to maintain optimal accuracy.
Final Thoughts
Product Summary
The AEMC CL601 Simple Logger II is a single-channel clamp-on current data logger designed for accurate current measurements. With its true RMS capability, easy one-button operation, and safety features, it is a reliable tool for various applications in electrical systems. The optically isolated USB ensures secure data transfer, and its durable construction ensures long-lasting performance.
Final Recommendation
If you’re in need of a user-friendly and accurate clamp-on current data logger, the AEMC CL601 Simple Logger II is highly recommended. Its features, reliability, and value for money make it a worthwhile investment for professionals and DIY enthusiasts alike.